SIKES

Show:
Sort By:

load Reactor dedicated for inverter testing 43A, 8.39mH

Load reactor is designed to test frequency inverter.Features of Three-phase load reactor:The windings adopt foil winding structure, which has small DC resistance, Strong at short circuit withstand capability and short time overload capability;The use of composite insulation materials with an insulat..

load Reactor dedicated for inverter testing 60A, 0.062mH

Load reactor is designed to test frequency inverter.Features of Three-phase load reactor:The windings adopt foil winding structure, which has small DC resistance, Strong at short circuit withstand capability and short time overload capability;The use of composite insulation materials with an insulat..

load Reactor dedicated for inverter testing 61A, 40Kva, Impedance rate 30%

Load reactor is designed to test frequency inverter.Features of Three-phase load reactor:The windings adopt foil winding structure, which has small DC resistance, Strong at short circuit withstand capability and short time overload capability;The use of composite insulation materials with an insulat..

load Reactor dedicated for inverter testing 730A, 0.48mH

Load reactor is designed to test frequency inverter.Features of Three-phase load reactor:The windings adopt foil winding structure, which has small DC resistance, Strong at short circuit withstand capability and short time overload capability;The use of composite insulation materials with an insulat..

Load Reactor for high speed motor, 400-1200Hz, 360A/380V

Description of Load Reactor:SKS-OCL series Load Reactors are placed in series with electrical equipment to introduce a specific controlled impedance to the AC circuit. This series are applied at AC drive output side to suppress inrush voltage, reducing inrush and peak current, improving real power f..

Load Reactor for high speed motor, 400-1200Hz, 550A/400V

Description of Load Reactor:SKS-OCL series Load Reactors are placed in series with electrical equipment to introduce a specific controlled impedance to the AC circuit. This series are applied at AC drive output side to suppress inrush voltage, reducing inrush and peak current, improving real power f..

Load Reactor for medium speed motor,320A/360V

Description of Load Reactor:SKS-OCL series Load Reactors are placed in series with electrical equipment to introduce a specific controlled impedance to the AC circuit. This series are applied at AC drive output side to suppress inrush voltage, reducing inrush and peak current, improving real power f..

Detuned Choke for reactive power compensation 2.1kva 480V, 7% drop

Description of  Detuned Choke:CKSGL series detuned chokes are placed in reactive power compensation application and used to prevent parallel resonance and amplification harmonic current occurring.Material Features  of  Detuned Choke:High heat resistance level, high insulation strength..

DC Filter dedicated for Rail Transit 33A

Description of  Rail Transit DC Filter:DC filter dedicated for railway air conditioning system . The train electrical system is very complex with many big power electrical devices resulting in severe electromagnetic interference . This products is specially designed for..

DC Filter dedicated for Rail Transit 33A

Description of  Rail Transit DC Filter:DC filter dedicated for railway air conditioning system . The train electrical system is very complex with many big power electrical devices resulting in severe electromagnetic interference . This products is specially designed for..